BLR100-1B-HG Optical Receiver (Plastic Shell)
- Introduction
- Parameters
1. With the best highly sensitive optical detector, low noises and distortion
2. With an external 5V DC power offer
3. With optical power LED level indicator, more easy for engineering commissioning
4. AGC fuction, RF output, CTB AND CSO will be stable when optical input in -2~-10 dBm
5. SC/ AGC AND FC/APC optical conection
Parameter |
Unit |
BLR100-1B-HG |
|
Bandwidth |
MHz |
45 ~ 1000 |
|
Optical Wavelength |
nm |
1210 ~ 1610 |
|
Optical Input |
dBm |
+2 ~ -15 |
|
AGC Range |
dBm |
-2 ~ -10 |
|
AGC Stability |
dB |
±1.0 |
|
Optical Return Loss |
dB |
≥45 |
|
Flatness |
dB |
±1.0 |
|
Reflection Loss |
dB |
≥14 |
|
Output Impedance |
Ω |
75 |
|
Output Level |
dBuV |
80±2(-2 ~ -10)dBm Receive |
|
CNR |
dB |
≥44 |
-9dBm optical power received,59 channel, PAL-D analog +16 digital channels |
CTB |
dB |
≥63 |
|
CSO |
dB |
≥63 |
|
MER |
dB |
≥32 |
-10dBm optical power received, 80-channel digital signal |
MER |
dB |
≥29 |
-15dBm optical power received, 80-channel digital signal |
Voltage |
AC\V |
5VDC(220V Transfer power adapter |
|
Operating Temperature |
℃ |
-40 ~ +60 |
|
Power Consumption |
W |
<3 |
|
Dimension |
mm |
95mm×65mm×25mm |
Explanation:
This equipment Parameter refer to CY/T143-2000 CATV System Optical Transmitter Modulated and Workstation Network Technical Conditioons and Methods of Measurement for testing. Base on the above methods of measurement, we can get the result as below: optical receiver, 10km standard optical and optical standard transmitters form in a test link, in the specified fonsumption, sets up with 59 sets PAL-D imitte television channel signals in 550MHz frequency rang. Transmits Digital Modulated Signal, the digital modulated signal (8MHz bandwidth) is less than carrier level of analog signal 10dB. The Optical receiver ootput is -1 dBm. Testing the CTB, CSO and C/N in 10dB.